Hose reel cart · SLA resin (Formlabs Form 4)
Hose Inlet
Diagnosed the worn-out, leaking inlet on a hose reel cart and redesigned it in SolidWorks as a sealed two-part print — 15% lighter, 20% more water flow, and the leak resolved.
- SolidWorks
- FEA
- Flow simulation
- SLA 3D printing
- Role
- Sole engineer — measurement, design, materials research, print orientation, validation
- Year
- Summer 2026
- CAD
- SolidWorks · parameterized
- Material
- SLA resin · Formlabs Form 4
- Process
- SLA (stereolithography) 3D printing
- Validation
- Static FEA · flow simulation
- Operating pressure
- 50 psi
- Connection
- 1 in diameter threads
Part weight
−15%
Water flow
+20%
flow simulation
Leak
Resolved
Peak von Mises
6.16MPa
from the FEA plot
Interactive — Analysis results
Female + male parts, assembled
- 6.163e+06
- 5.547e+06
- 4.930e+06
- 4.314e+06
- 3.698e+06
- 3.082e+06
- 2.465e+06
- 1.849e+06
- 1.233e+06
- 6.163e+05
- 1.361e+01
- 2.297e-03
- 2.067e-03
- 1.838e-03
- 1.608e-03
- 1.378e-03
- 1.149e-03
- 9.188e-04
- 6.891e-04
- 4.594e-04
- 2.297e-04
- 5.072e-09
Problem
The inlet on a hose reel cart had simply worn out. Years of overuse, freezing and cracking fatigued the part until it no longer sealed, and it leaked water. The original part also carried excess, unoptimized material that restricted its flow.
Constraints
- Leak-free at 50 psi of water pressure.
- Structural integrity had to be maintained while removing material.
- Manufacturing: SLA resin, printed on a Formlabs Form 4. Print orientation affects strength and surface finish, and the process limits wall thickness and supports.
- Interfaces: mounts on the hose reel cart and connects to the hose through 1 in diameter threads.
Approach
I owned the project end to end — from measuring the existing part through design, materials research, print setup and validation.
- Measured the existing inlet and diagnosed the leak, and identified where excess, unoptimized material was restricting flow. The leak came from age: fatigue, freezing and cracking had left the old part unsealed.
- Redesigned the part in SolidWorks with parameterized dimensions, so the geometry could be tuned without rebuilding the model. The redesign eliminated the leak, streamlined the internal geometry, and added an alternative connection for the hose.
- Split the inlet into two parts. The male part carries two O-ring grooves, where rubber O-rings seat to seal the water out. The female part receives it and connects to the hose. Threads were left off the analysis model, because a thread can’t be meshed cleanly for FEA.
- Researched the material and print orientation for SLA resin on the Formlabs Form 4. I chose the orientation that let the resin cure best, so the part resists water and lasts under repeated use.
- 3D-printed the revised design in SLA resin as the two-part assembly.
Analysis & Results
The redesign was checked with a static structural study and a flow simulation. The threads were omitted from the FEA model so it could be meshed cleanly.
| Quantity | Value |
|---|---|
| Peak von Mises stress | 6.163 MPa (6.163 × 10⁶ N/m²) |
| Peak equivalent strain | 2.297 × 10⁻³ (0.23%) |
| Water flow vs. original | +20% (flow simulation) |
| Part weight vs. original | −15% |
| Applied load | 50 psi internal water pressure (≈ 345 kPa) |
| Failure criterion | von Mises stress vs. resin yield strength |
Stress is highest along the horizontal run, with a smaller hot spot at the bend near the top of the riser. The flange, the elbow and the couplers stay at the low end of the scale. Strain follows the same pattern. Switch between the Stress and Strain views above and hover the colour scale to read values.
Why von Mises: a pressurized pipe wall carries stress in several directions at once (hoop, axial and radial). Von Mises combines them into one equivalent stress that can be compared directly with the resin’s yield strength, so it is the right check for a ductile-behaving part. Under 50 psi, the peak is 6.163 MPa, along the horizontal run.
Outcome
- Leak resolved.
- 15% lighter than the original part.
- 20% more water flow, confirmed in flow simulation.
- Structural integrity maintained.
What I’d do next
Test the printed inlet on a real hose at a constant 50 psi, to see how much it can withstand and for how long, and use the results to improve my design and print process.
Gallery — 5 figures
FIG. 01Redesigned inlet assembly (SolidWorks). FIG. 02Female part — connects to the hose. FIG. 03Male part — the two O-ring grooves seat the rubber seals that keep water out. FIG. 04Static study — von Mises stress. Peak 6.163 MPa. FIG. 05Static study — equivalent strain. Peak 2.297 × 10⁻³.