Hose Inlet

Diagnosed the worn-out, leaking inlet on a hose reel cart and redesigned it in SolidWorks as a sealed two-part print — 15% lighter, 20% more water flow, and the leak resolved.

  • SolidWorks
  • FEA
  • Flow simulation
  • SLA 3D printing
Role
Sole engineer — measurement, design, materials research, print orientation, validation
Year
Summer 2026
CAD
SolidWorks · parameterized
Material
SLA resin · Formlabs Form 4
Process
SLA (stereolithography) 3D printing
Validation
Static FEA · flow simulation
Operating pressure
50 psi
Connection
1 in diameter threads

Part weight

−15%

Water flow

+20%

flow simulation

Leak

Resolved

Peak von Mises

6.16MPa

from the FEA plot

Interactive — Analysis results

Female + male parts, assembled

CAD model of the redesigned hose inlet assembly

von Mises (Pa)
  • 6.163e+06
  • 5.547e+06
  • 4.930e+06
  • 4.314e+06
  • 3.698e+06
  • 3.082e+06
  • 2.465e+06
  • 1.849e+06
  • 1.233e+06
  • 6.163e+05
  • 1.361e+01
ESTRN
  • 2.297e-03
  • 2.067e-03
  • 1.838e-03
  • 1.608e-03
  • 1.378e-03
  • 1.149e-03
  • 9.188e-04
  • 6.891e-04
  • 4.594e-04
  • 2.297e-04
  • 5.072e-09

Problem

The inlet on a hose reel cart had simply worn out. Years of overuse, freezing and cracking fatigued the part until it no longer sealed, and it leaked water. The original part also carried excess, unoptimized material that restricted its flow.

Constraints

  • Leak-free at 50 psi of water pressure.
  • Structural integrity had to be maintained while removing material.
  • Manufacturing: SLA resin, printed on a Formlabs Form 4. Print orientation affects strength and surface finish, and the process limits wall thickness and supports.
  • Interfaces: mounts on the hose reel cart and connects to the hose through 1 in diameter threads.

Approach

I owned the project end to end — from measuring the existing part through design, materials research, print setup and validation.

  1. Measured the existing inlet and diagnosed the leak, and identified where excess, unoptimized material was restricting flow. The leak came from age: fatigue, freezing and cracking had left the old part unsealed.
  2. Redesigned the part in SolidWorks with parameterized dimensions, so the geometry could be tuned without rebuilding the model. The redesign eliminated the leak, streamlined the internal geometry, and added an alternative connection for the hose.
  3. Split the inlet into two parts. The male part carries two O-ring grooves, where rubber O-rings seat to seal the water out. The female part receives it and connects to the hose. Threads were left off the analysis model, because a thread can’t be meshed cleanly for FEA.
  4. Researched the material and print orientation for SLA resin on the Formlabs Form 4. I chose the orientation that let the resin cure best, so the part resists water and lasts under repeated use.
  5. 3D-printed the revised design in SLA resin as the two-part assembly.

Analysis & Results

The redesign was checked with a static structural study and a flow simulation. The threads were omitted from the FEA model so it could be meshed cleanly.

QuantityValue
Peak von Mises stress6.163 MPa (6.163 × 10⁶ N/m²)
Peak equivalent strain2.297 × 10⁻³ (0.23%)
Water flow vs. original+20% (flow simulation)
Part weight vs. original−15%
Applied load50 psi internal water pressure (≈ 345 kPa)
Failure criterionvon Mises stress vs. resin yield strength

Stress is highest along the horizontal run, with a smaller hot spot at the bend near the top of the riser. The flange, the elbow and the couplers stay at the low end of the scale. Strain follows the same pattern. Switch between the Stress and Strain views above and hover the colour scale to read values.

Why von Mises: a pressurized pipe wall carries stress in several directions at once (hoop, axial and radial). Von Mises combines them into one equivalent stress that can be compared directly with the resin’s yield strength, so it is the right check for a ductile-behaving part. Under 50 psi, the peak is 6.163 MPa, along the horizontal run.

Outcome

  • Leak resolved.
  • 15% lighter than the original part.
  • 20% more water flow, confirmed in flow simulation.
  • Structural integrity maintained.

What I’d do next

Test the printed inlet on a real hose at a constant 50 psi, to see how much it can withstand and for how long, and use the results to improve my design and print process.

  • FIG. 01Redesigned inlet assembly (SolidWorks).
  • FIG. 02Female part — connects to the hose.
  • FIG. 03Male part — the two O-ring grooves seat the rubber seals that keep water out.
  • FIG. 04Static study — von Mises stress. Peak 6.163 MPa.
  • FIG. 05Static study — equivalent strain. Peak 2.297 × 10⁻³.